China TY-WQ1000 Pipe Network Water Quality Monitoring System - China Supplier
China TY-WQ1000 Pipe Network Water Quality Monitoring System - China Supplier

TY-WQ1000 Pipe Network Water Quality Monitoring System

Price:1
Industry Category: Measurement-Analysis-Instruments
Product Category:
Brand: 陕西天韵
Spec: TY-WQ1000


Contact Info
  • Add:西安市高新区唐延南路11号, Zip:
  • Contact: 谭东东
  • Tel:13720774318
  • Email:509857967@qq.com

Other Products

Description
Additional Information

Product Introduction

The pipe network water quality monitoring system is a product developed for online water quality monitoring applications in drinking water. It features a compact size, lightweight design, and convenient on-site installation. This product integrates water quality analysis sensors, data acquisition and processing units, and internal water flow pipeline units, enabling continuous measurement of parameters such as temperature, pH, turbidity, and disinfectant indicators. The system can be externally expanded to connect with standard MODBUS RS485 output instruments of any brand, such as flow, pressure, chroma, and other parameters.

MainFeatures

1)High integration of internal wiring and water circuits; users only need to connect the power supply and water inlet/outlet, making on-site installation convenient;

2)The internal water circuit design ensures stable water flow during the measurement process, guaranteeing accurate monitoring data;

3)Equipped with automatic fault diagnosis function, including abnormal information recording and uploading, such as component failures, over-range alarms, and超标 alarms;

4)Three-level password permission management;

5)Data storage function, with data displayable in tables and curves;

6)Optional built-in wireless data transmission module for data acquisition and wireless transmission;

7)Supports on-site program upgrades via USB drive;

Typical Applications

ØWater quality monitoring in tap water plants, water supply networks, secondary water supply, and rural tap water systems;

ØReal-time water quality monitoring in swimming pools, SPAs, etc.

Main Unit PhysicalSpecifications

Display

7-inch touch screen with a simple operation interface

Power Supply

AC power: 85~500VAC; DC power: 9~36VDC

Output

8 channels of 4-20mA analog output (optional)

Relay

Four relays, with programmatically set response parameters and values

Communication Protocol

Standard MODBUS RS485 communication function for real-time transmission of measured values

Wireless communication methods: 4G: UDP/TCP NB: UDP (optional)

Storage Temperature

0~40℃

Operating Temperature

0~45℃ (non-freezing)

Protection Level

IP54

Residual Chlorine

Total Chlorine

Chlorine Dioxide

Principle

Electrode Method

Turbidity

Principle

Light Scattering

Range

0-2ppm/0-20ppm

Range

0-100NTU

Resolution

0.01ppm

Resolution

0.001~0.1NTU, depending on the range

Accuracy

Refer to detailed specifications of different electrodes

Accuracy

±2% of reading or ±0.015NTU, whichever is greater, for 0.001-40NTU; ±5% of reading for 40-100NTU

pH

Principle

Glass Electrode Method

Temperature

Principle

Thermistor Method

Range

0-14 pH

Range

0℃~40℃

Resolution

0.01 pH

Resolution

0.1℃

Accuracy

±0.1 pH

Accuracy

±0.5℃

Monitoring Parameter Specifications

Industry Category Measurement-Analysis-Instruments
Product Category
Brand: 陕西天韵
Spec: TY-WQ1000
Stock:
Origin: China / Shaanxi / Xianshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192